故障原因:電源插頭鬆脫、插座損壞、內部保險絲燒斷、主板供電模塊燒毀、電源變壓器故障。
自查:換其他電器測插座、重插電源;若仍無反應多為內部電路零件損壞,需維修更換保險絲 / 主板。
Fault Cause: Loose plug, faulty socket, blown fuse, burnt main power board, transformer failure.
Self Check: Test socket with other appliance, re-plug power; if no response, internal circuit parts damaged, fuse/main board replacement needed.
故障原因:啟動電容老化、壓縮機過熱保護、溫控探頭故障、主板未發送製冷信號。
自查:關機靜置 30 分鐘重開;溫度調至最低測試;無改善需更換啟動電容或溫度感應器。
Fault Cause: Aging start capacitor, compressor overheat protection, faulty temperature sensor, main board signal error.
Self Check: Power off & rest 30 mins, set temp to lowest; replace capacitor/sensor if no improvement.
故障原因:冷凝器積灰、門封漏冷、雪種洩漏、風扇停轉。自查:清理背部灰塵,夾紙測門封密封性。
Cause: Dirty condenser, leaky seal, refrigerant leak, fan stop. Self check: Clean back dust, test seal with paper.
故障原因:溫控探頭損壞、主板控溫故障。自查:檢查感溫頭是否被酒瓶遮擋。
Cause: Broken temp sensor, main board control error. Self check: Clear sensor blocked by bottles.
故障原因:門封膠條硬化、鉸鏈鬆動、磁吸老化。自查:熱毛巾軟化膠條、擰緊門鉸。
Cause: Hardened seal, loose hinge, weak magnet. Self check: Soften seal with hot towel, tighten hinge screws.
故障原因:門封漏氣、除霜絲燒斷、排水孔堵塞。自查:減少開門次數、疏通排水孔。
Cause: Air leak seal, broken heater, clogged drain. Self check: Reduce door opening, clear drain hole.
故障原因:排水孔堵塞、接水盤破裂、凝露過多。自查:疏通排水、清洗檢查接水盤。
Cause: Clogged drain, cracked water tray, excess condensation. Self check: Clear drain, clean & inspect tray.
故障原因:壓縮機腳墊老化、機身不平、風扇碰殼。自查:調整機腳放平、清理風扇雜物。
Cause: Aged compressor pad, uneven cabinet, fan collision. Self check: Level feet, clear fan debris.
故障原因:循環風扇馬達燒毀、供電線鬆脫。自查:開門觀察風扇轉動狀態。
Cause: Burnt fan motor, loose wiring. Self check: Open door check fan rotation.
故障原因:主板程式故障、面板接觸不良。自查:斷電5分鐘重啟復位。
Cause: Main board program error, loose display cable. Self check: Power off 5 mins reset system.
故障原因:LED燈條燒毀、燈控開關損壞。自查:開關門測試燈控按鈕。
Cause: Burnt LED strip, faulty door light switch. Self check: Open/close door test switch.
故障原因:壓縮機過熱保護、散熱堵塞、電壓不穩。自查:清理冷凝器、機身留10cm散熱空間。
Cause: Compressor overheat protection, blocked heat vent, unstable voltage. Self check: Clean condenser, leave 10cm gap around unit.
故障原因:分區風扇、獨立溫控、電磁閥故障。自查:對比兩區風扇轉動狀態。
Cause: Zone fan, separate sensor, solenoid valve fault. Self check: Compare fan operation of two zones.
故障原因:電線短路、壓縮機/風扇燒毀。自查:立刻斷電停用,勿開機,聯絡維修。
Cause: Short circuit, burnt compressor/fan motor. Self check: Cut power immediately, stop usage contact repairman.
故障原因:周圍無散熱縫、門封被櫥櫃擠壓漏冷。自查:確認四周預留通風空隙。
Cause: No ventilation gap, seal squeezed by cabinet. Self check: Leave ventilation space around unit.
故障原因:鎖芯生鏽、彈簧斷裂。自查:少量潤滑油測試,卡死需整套換鎖。
Cause: Rust lock cylinder, broken spring. Self check: Apply lubricant, full lock replacement if stuck.
故障原因:恆濕模塊故障、儲水盒缺水、門封漏氣。自查:補滿儲水盒、關緊門體。
Cause: Humidity module fault, empty water tank, air leak seal. Self check: Refill water tank, close door tightly.
故障原因:線路短路、壓縮機漏電。自查:禁止重複開機,存在漏電危險直接維修。
Cause: Short circuit, compressor electric leakage. Self check: Do not restart, dangerous contact repair service directly.
故障原因:濕度過高、排水堵塞、長期不通風。自查:清空徹底乾燥,調低濕度設定。
Cause: Over high humidity, clogged drain, no ventilation. Self check: Empty & fully dry cabinet, lower humidity setting.
故障原因:搬運傾斜,冷凍油堵塞管路。自查:斷電靜置24小時讓油回流,依舊不製冷需重新加雪種。
Cause: Over tilted during transport oil block pipe. Self check: Power off rest 24hrs for oil flow back, re-gas refrigerant if still no cooling.
描述故障、提供機型、地址,初步報價
Describe fault, model & address for initial quote
配合閣下時間安排技師到場檢測
Arrange technician visit per your schedule
拆解檢查電路、壓縮機、門封、溫控零件
Disassemble & test circuit, compressor, seal, sensor
告知損壞零件,同意後才展開維修
Inform damaged parts, start repair only after approval
原廠配件替換,運行30分鐘確認穩定
Original spare parts, 30mins running stability test
清潔機身,提供維修保養期保障
Clean unit, offer repair warranty period