1. 紅酒櫃完全不開機、屏幕無燈、毫無反應Cabinet no power, screen off, no response
+
故障原因:Fault Cause:
電源插頭鬆脫、插座損壞、內部保險絲燒斷、主板供電模塊燒毀、電源變壓器故障
Loose plug, broken socket, blown fuse, burnt mainboard power module, faulty transformer
自查方法:Self Check:
替換其他電器測試插座、重新插緊電源;依舊無反應代表內部電子零件損壞,需維修更換保險絲或主控板
Test socket with other appliance, re-plug power; still dead means internal parts damaged, replace fuse/mainboard
2. 通電有燈,但壓縮機不啟動、完全不製冷Power light on but compressor won’t start, no cooling
+
故障原因:Fault Cause:
啟動電容老化、壓縮機過熱保護、溫控探頭故障、主板未輸出製冷訊號
Aged start capacitor, compressor overheat lockout, faulty temp sensor, no cooling signal from mainboard
自查方法:Self Check:
關機靜置30分鐘後重啟;溫度調至最低測試;無改善需更換啟動電容或溫度感應器
Power off & rest 30 mins then restart; set temp to lowest; replace capacitor/temp sensor if no improvement
3. 製冷差、溫度降不下,酒品長期偏熱Poor cooling, temperature cannot drop, wine warm
+
故障原因:Fault Cause:
冷凝器積灰散熱差、門封膠條漏冷、冷媒輕微洩漏、循環風扇停轉
Dusty condenser poor heat dissipation, cold leak from door seal, refrigerant leak, circulation fan stall
自查方法:Self Check:
清理機背灰塵;關門夾紙測密封性,紙可輕易抽出即膠條老化
Clean dust on back condenser; test seal with paper, easy pull-out means aged gasket
4. 溫度過低凍結酒瓶、背板結厚冰Over cooling, wine bottles frozen, thick ice on back panel
+
故障原因:Fault Cause:
溫控探頭移位損壞、主板控溫程式異常、風扇長時間持續運轉
Displaced/damaged temp sensor, faulty mainboard control program, fan run nonstop
自查方法:Self Check:
檢查感溫頭是否被酒瓶遮擋;無法回溫需更換溫度感應器
Check sensor blocked by bottles; replace temp sensor if cannot warm up
5. 門關不緊、自動彈開、持續漏冷跑溫Door cannot close tight, pop open, constant cold loss
+
故障原因:Fault Cause:
門封膠條硬化變形、鉸鏈鬆動、層架酒瓶頂門、磁吸老化
Hard deformed door gasket, loose hinge, bottles push door, aged magnetic strip
自查方法:Self Check:
熱毛巾敷軟膠條整形;擰緊鉸鏈螺絲;整理內部酒品避免頂住門體
Use hot towel soften gasket & reshape; tighten hinge screw; rearrange bottles
6. 櫃內結霜、背板厚冰,無霜機亦結冰Heavy frost & ice on back, frost-free model icing up
+
故障原因:Fault Cause:
門封漏氣進熱氣、除霜加熱絲燒斷、除霜定時器故障、排水孔堵塞積冰
Hot air leak via door seal, burnt defrost heater, faulty defrost timer, blocked drain hole
自查方法:Self Check:
減少頻繁開門;疏通底部排水孔;持續結霜需維修除霜配件
Reduce frequent door opening; unclog drain hole; repair defrost parts if frost persists
7. 機底漏水、地面長期濕漉Water leak at bottom, wet floor constantly
+
故障原因:Fault Cause:
排水孔髒污堵塞、接水盤移位破裂、門封凝露過多、除霜水溢出
Clogged drain tray, displaced cracked water pan, excess condensation, overflow defrost water
自查方法:Self Check:
斷電疏通排水孔;抽出接水盤清洗檢查裂損
Power off unclog drain; pull out water pan clean & check crack
8. 運行噪音震動極大,全屋可聽見Extreme running noise & vibration heard all room
+
故障原因:Fault Cause:
壓縮機減震腳墊老化、機身不平、風扇葉片碰殼、管路共振、壓縮機內部磨損
Aged compressor rubber pad, uneven cabinet, fan blade hit shell, pipe resonance, internal compressor wear
自查方法:Self Check:
調整底部調腳放平;清理風扇周圍雜物;異響持續更換風扇或減震墊
Adjust foot leveller flat; clear debris around fan; replace fan/shock pad if noise remains
9. 內循環風扇不轉、櫃內溫度分佈不均Internal circulation fan stop spinning, uneven cabinet temp
+
故障原因:Fault Cause:
風扇馬達燒毀、供電線鬆脫、主板風扇控制模塊故障
Burnt fan motor, loose power wire, faulty fan control module on mainboard
自查方法:Self Check:
開門觀察風扇轉動狀態;完全不轉需更換整套風扇馬達
Open door observe fan rotation; full fan motor replacement if no spin
10. 數碼屏幕亂跳、錯誤代碼、溫度顯示不準Digital screen flicker, error code, wrong temp reading
+
故障原因:Fault Cause:
主板程式異常、顯示面板接觸不良、溫度探頭數據異常
Mainboard program error, loose display panel wire, abnormal sensor data
自查方法:Self Check:
斷電5分鐘重啟復位;依舊亂碼維修更換顯示板或主控板
Power off 5 mins hard reset; replace display/mainboard if error persists
11. 內部LED燈完全熄滅不亮Internal LED light fully dead
+
故障原因:Fault Cause:
LED燈條燒毀、門燈控開關損壞、燈具供電線斷路
Burnt LED strip, faulty door light switch, broken lamp wire
自查方法:Self Check:
開關門測試燈控按鈕;無反應直接更換燈條總成
Open/close door test light switch; full LED strip replacement if no light
12. 運行一段自動停機,間隔一段又重啟Auto shutdown after running, restart later automatically
+
故障原因:Fault Cause:
壓縮機過熱保護、冷凝器散熱堵塞、電壓不穩、主板過溫保護
Compressor thermal cutout, blocked condenser heat dissipation, unstable voltage, mainboard overheat lock
自查方法:Self Check:
清理機背灰塵;機身兩側預留最少10cm散熱空間
Clean back dust; leave minimum 10cm gap on both sides for ventilation
13. 雙溫區酒櫃一層正常、另一層完全不製冷Dual zone cabinet one side cool, another no cooling
+
故障原因:Fault Cause:
分區獨立風扇損壞、分區溫控探頭故障、雙循環管路堵塞、電磁閥故障
Broken zone fan, zone temp sensor fault, blocked dual cycle pipe, faulty solenoid valve
自查方法:Self Check:
對比兩區風扇轉動狀態;單區異常多為分區專屬配件損壞
Compare fan rotation of two zones; single zone fault means zone parts damaged
14. 機體傳出燒焦塑膠、電路異味Burnt plastic / circuit smell from cabinet
+
故障原因:Fault Cause:
內部電線短路、壓縮機過熱燒蝕、風扇馬達燒毀、主板元件燒熔
Internal wire short circuit, burnt overheat compressor, melted fan motor, burnt mainboard chip
自查方法:Self Check:
立刻斷電停止使用,避免起火風險,馬上聯絡維修檢查線路
Cut power immediately stop use to avoid fire risk, contact repairman for circuit inspection
15. 嵌入式酒櫃製冷長時間無法降溫Built-in cabinet cooling weak, temp cannot drop long time
+
故障原因:Fault Cause:
櫥櫃封死無散熱縫、背板隔板阻擋通風、門封被櫃體擠壓漏冷
No ventilation gap in cabinetry, back plate block airflow, door seal squeezed cold leak
自查方法:Self Check:
上下左右預留通風縫;拆除阻礙散熱的封閉背板隔板
Leave ventilation gap all sides; remove back panel blocking heat exhaust
16. 門鎖頭損壞、鑰匙斷鎖芯內、無法開關上鎖Door lock broken, key stuck inside, cannot lock/unlock
+
故障原因:Fault Cause:
鎖芯生鏽磨損、鎖舌彈簧斷裂、兒童鎖機構卡滯
Rusty worn lock cylinder, broken latch spring, jam child lock mechanism
自查方法:Self Check:
少量潤滑油輕試;完全卡死需整套門鎖替換
Try tiny lubricant oil; full lock assembly replacement if fully jammed
17. 櫃內濕度過低、軟木塞乾裂,只控溫不控濕Low humidity crack cork, temp control only no humidity control
+
故障原因:Fault Cause:
恆濕模塊故障、加濕儲水盒缺水、濕度探頭失效、門封漏氣水分流失快
Broken humidity module, empty water tray, faulty humidity sensor, moisture loss via seal leak
自查方法:Self Check:
補滿專用儲水盒;關緊門體;濕度持續偏低更換濕度感應器
Refill dedicated water tray; close door tight; replace humidity sensor if dry persist
18. 開機立即跳掣、一運作就全屋斷電Trip circuit breaker immediately after power on
+
故障原因:Fault Cause:
內部線路短路、壓縮機繞組擊穿、風扇漏電、接地故障
Internal wire short circuit, compressor winding breakdown, fan electric leakage, ground fault
自查方法:Self Check:
切勿重複開機,漏電短路存在火災觸電危險,直接預約維修檢測
Do not restart repeatedly, electric leakage risk shock & fire, book repair inspection directly
19. 木質層架發霉、櫃內產生異味霉味Wood shelf moldy, bad mildew smell inside cabinet
+
故障原因:Fault Cause:
濕度設定過高、排水堵塞積水、長期不開門通風、門封滲入潮氣
Over high humidity setting, blocked drain water, no ventilation long term, moisture leak via seal
自查方法:Self Check:
清空酒櫃徹底擦拭乾燥;調低濕度;疏通底部排水系統
Empty cabinet fully wipe dry; lower humidity setting; unclog drain system
20. 搬運移動後完全不製冷,機器運轉但不凍No cooling after moving cabinet, compressor run but coldless
+
故障原因:Fault Cause:
搬運傾斜角度過大,壓縮機冷凍油倒流堵塞冷媒管路
Over tilt during transport, compressor oil flow block refrigerant pipe circulation
自查方法:Self Check:
斷電靜置24小時讓冷凍油回流;靜置後依舊不製冷需重新抽真空加注雪種
Power off rest 24hr for oil flow back; re-vacuum & refill refrigerant if still no cooling